Science Gateway
Radioisotope
Calcium - 45
Carbon - 14
Chromium - 51
Hydrogen - 3
Iodine - 125
Iron - 59
Manganese - 54
Phosphorus - 32
Phosphorus - 33
Sodium - 22
Sulfur - 35

MANGANESE - 54

(54Mn)

Physical Half-life: 312.5 days
Radiations:Gamma 835 (99.9%)keV
External Exposure:External hazard. Radiation exposures from 1 mCi source of 54Mn are 188 mR/hr and 47 mR/hr @ 5cm and 10 cm, respectively.
Biological Data: ALI 2 mCi (ingestion), 0.9 mCi (inhalation)
Biological half-life 25 days
Effective half-life 23 days
Critical Organs Liver and Gastrointestinal Tract
Bioassay Urinalysis (Not routinely done.)
Shielding: HVL 0.74 cm of lead; TVL 2.46 cm of lead
Monitoring
& Efficiency
LSC (Eff. ~30%)
NaI Gamma Counter (Eff. ~5%)
Thin-window GM (Eff. <1%)

Special Considerations

  • Use forceps with rubber sleeves to handle unshielded sources and potentially contaminated vessels, and work at arms length.
  • Always store 54Mn vials in lead containers or behind shields.
  • Wear a radiation badge when handling 1.0 mCi or more.